Product Details:
Payment & Shipping Terms:
|
Applicable Industries: | Food & Beverage Factory, Home Use, Dental, Lab | Showroom Location: | None |
---|---|---|---|
Video Outgoing-inspection: | Provided | Machinery Test Report: | Provided |
Marketing Type: | New Product 2023 | Warranty Of Core Components: | 1 Year |
Core Components: | Sterilizer | Condition: | New |
Voltage: | AC220V/50HZ | Weight: | 60 KG |
Dimension(L*W*H): | 67*50*45cm | Warranty: | 1 Year |
Key Selling Points: | Easy To Operate | Chamber Volume: | 24l |
Working Pressure: | 0.22MPa | Working Temperature: | 134 Degrees Celsius |
Max Working Pressure: | 0.23 Mpa | Heat Average: | ≤2℃ |
Timer: | 0-99 Min | Adjustment Of Temperature: | 55℃~134℃ |
Power: | AC220V/50HZ | Sterilizing Plate: | 67*50*45cm |
G.W N.W: | 60kg/50kg | Port: | Tianjin/SHANGHAI,ningbo |
Chamber Volume: | 20 Liters(φ250×350 mm) | 24 Liters(φ250×430 mm) | 35Liters | 50 Liters |
Max working temperature: | 134℃±1℃ | 134℃±1℃ | 134℃±1℃ | 134℃±1℃ |
Max working pressure: | 0.23mpa | 0.22mpa | 0.22mpa | 0.22mpa |
Adjusted sterilizing temperature range: | 55℃~134℃ | 55℃~134℃ | 55℃~134℃ | 55℃~134℃ |
Adjusted timer range: | 1~99mins | 1~99mins | 1~99mins | 1~99mins |
Adjusted drying time range: | 1~99mins | 1~99mins | 1~99mins | 1~99mins |
Vacuum limit: | -0.08mpa | -0.08mpa | -0.08mpa | -0.08mpa |
Hot Average: | ≤2℃ | ≤2℃ | ≤2℃ | ≤2℃ |
Power supply: | AC220V/50HZ | AC220V/50HZ | AC220V/50HZ | AC220V/50HZ |
Dimension: | 67*50*45cm | 67*50*45cm | 730×550×510 mm | 770×600×540 mm |
Transport dimension: | 70*58*60cm | 80*58*55cm | 810×680×650 mm | 880×730×700 mm |
Gross/Net Weight | 54kg/47kg | 60kg/50kg | 115/93 kg | 130/106 kg |
The sterilizing procedure is automatically controlled, it is not necessary to be supervised, and used conveniently. 2.At lease 3 or more times pulse-vacuum exhausting, which is applied to wrapped or unwrapped objects,hollow equipment. 3.Drying function. 4.With inner printer, which record the for the full procedure of the sterilization. 5.With Bowie testing function, which is for the steam penetrating testing. 6.Self-testing malfunction, easy to maintain. 7.Safety functions: Safety locking: the steam can not enter the chamber and the unit will alarm when the door is not closed tightly,and the door can not the open when the inner pressure is exceed 0.027mpa. Over pressure protection: If the pressure exceed the working pressure, the safety valve will exhausting the air. Low water protection: The unit can not be started if the water don’t reach the high level,and the power will cut off directly. Over current protection: The broker will cut off the power by the over current happened.